A brake pad is to be analyzed under use. What factor may prevent the effective use of linear-static analysis in this case? 

(Select one)
Select an answer

An imported model consists of multiple surfaces. These surfaces almost enclose a volume but include small gaps near where their surfaces meet. Which tool can be used to repair these gaps? 

(Select one)
Select an answer

A design is suspended by two pins. Which constraint would adequately capture this scenario?

(Select one)
Select an answer

For a component that is to undergo an iterative loop of simulations and design changes, what is the key benefit to model simplification?

(Select one)
Select an answer

Illustrated below are the stress and displacement results of a linear static study performed on a mild steel clip. Mild steel has a yield strength of 207MPa and an Ultimate Tensile Strength of 345MPa. What conclusion can be made with certainty from this simulation?

(Select one)
Select an answer

A hole in a design has a rod inserted into it. The rod is then pulled radially, acting on the inner surface of the hole. Which of the following is the most suitable Structural Load to simulate the approximate stress in the hole because of the rod?

(Select one)
Select an answer

A design subject to a fixed load is recalculated using various materials. Increasing which material property below will result in smaller deflection?

(Select one)
Select an answer

For the study illustrated below, which constraint would be most suitable to allow the hammer to rotate about its axis?

(Select one)
Select an answer

Illustrated below are the stress and displacement results for an aluminum design subject to torsion. The yield strength of this grade of aluminum is 275MPa. Assume the mesh is of sufficient quality. Which of the following statements is true?

(Select one)
Select an answer

A shaft undergoes torsion. Which of the following loads would be used to specify this rotational load?

(Select one)
Select an answer

Local mesh controls are being used in an analysis, greatly refining the mesh in areas of interest. Which of the following global mesh settings is most suitable for making the transition from course mesh to fine mesh more gradual?

(Select one)
Select an answer

An imported model consists of multiple surfaces. Together, these surfaces connect with no gaps or overlaps, and enclose a volume. Which tool would produce a solid model of the enclosed volume?

(Select one)
Select an answer

A small frame consisting of natural wooden planks bolted together requires analysis. What is the most serious concern when performing a linear-static stress analysis on such a frame?

Select up to undefined
Select an answer

Which constraint is most suitable for defining symmetry on a cut surface?

(Select one)
Select an answer

For the study illustrated, which constraint could replace the frictionless constraint used?

(Select one)
Select an answer

The Pre-Check tool has returned the message, “The study setup has all the information required.” Even though this is a green-light, what issues may become apparent after the simulation is complete?

(Select one)
Select an answer

A linear static analysis is conducted on a given design. There is significant deformation in the part, with peak deflection equal to approximately 10% of the original length. Which statement below is true?

(Select one)
Select an answer

Which of the following statements regarding the Simplify tool is false?

(Select one)
Select an answer

A linear static study has returned a very high value for Von Mises stress, localized in a small region near a sharp internal corner. Mesh refinement appears to only increase this stress. What is the most likely cause of this scenario?

(Select one)
Select an answer

A design includes two faces angled 135 degrees from one another. A single Force load is applied to both faces. Which of the following statements is false?

(Select one)
Select an answer

Which of the following properties is not needed for a linear static study involving a gravitational load?

(Select one)
Select an answer

A design is intended to undergo some yield, but not break. In the Study Materials dialog, what might an analyst define as the metric for Safety Factor?

(Select one)
Select an answer

A linear static study with a single Load Case is to be repeated using a variety of materials. How can an analyst complete these simulations while retaining the results of each?

(Select one)
Select an answer

The simulation illustrated below consists of two forces in equilibrium, and no structural constraints. Without adding constraints, how can a user ensure this load case will compute?

(Select one)
Select an answer

Which of the following statements describes what happens with regard to rough contacts created between two surfaces?

(Select one)
Select an answer

A design is accelerating horizontally at 5m/s2. What is the best way to simulate this loading?

(Select one)
Select an answer

A highly flexible fishing rod requires stress analysis. Which of the following statements is true?

(Select one)
Select an answer

A linear static solution has returned an extremely high value for Von Mises stress, localized in a small region near a sharp internal corner. An approximate value for the true stress in this corner is required. Which of the following is likely to produce a good approximate for the stress?

(Select one)
Select an answer

When importing models for stress analyses, what file types are most appropriate?

(Select one)
Select an answer

Adaptive mesh refinement is an automated way to apply local mesh refinements. Specifically, the Adaptive Mesh Refinement Tool operates how?

(Select one)
Select an answer

For a linear-static analysis, the Pre-Check tool has returned: “Some components are using a material with invalid properties. Which of the following options is not a valid approach to reconciling this error?

(Select one)
Select an answer

An imported model consists of multiple surfaces. Together, these surfaces would connect with no gaps or overlaps, enclosing a volume; however, a single, large surface is missing. Which tool would be most suitable to recreate the missing surface?

(Select one)
Select an answer

There exists a very high (but accurate) value for Von Mises stress in a large fillet. What modification is likely to decrease the stress in this region?

(Select one)
Select an answer

A design includes a connection point somewhere along its body. Specifications require that, under load, the position of this connection point cannot deviate more than 2mm from its starting position. Assuming that the connection point is not in the region of maximum deflection for the design, how could an analyst determine whether or not it is within specification?

(Select one)
Select an answer

Which of the following global mesh configurations is likely to produce the most accurate results, assuming that there are no stress singularities?

(Select one)
Select an answer

What is the easiest way to achieve a desired displacement on a given surface?

(Select one)
Select an answer

A linear static analysis has been computed for a design. Which metric below would correspond to the maximum tensile stress experienced throughout the design?

(Select one)
Select an answer

The Pre-Check tool has returned, “Warning: Missing Gravity while Point Mass is defined in load case “Load Case 1”.” Which of the following options is not a valid approach to reconciling this warning?

(Select one)
Select an answer

An assembly consisting of many parts of different materials is subject to a load. After undergoing a linear static stress analysis, an analyst wishes to determine if plastic deformation occurs in any of the parts. Which metric would be most efficient in determining if plastic deformation is occurring in any of the parts?

(Select one)
Select an answer

Which material property below measures the stress at which a material will plastically deform?

(Select one)
Select an answer

When formulating a load case for a linear-static study, which of the following is the most suitable definition for the load applied?

(Select one)
Select an answer

A linear static analysis has been completed on a design. However, the stress results appear as illustrated below. What is a likely cause for these results?

(Select one)
Select an answer

When collecting information for a linear-static study, which of the following are not required? 

(Select one)
Select an answer

An assembly consists of two tubes. The tube of smaller diameter is nested coaxially within the tube of larger diameter; there exists only a small gap between the outer surface of the smaller tube and the inner surface of the larger tube. The inner tube can translate axially and rotate about its axis. Which of the following contacts is most suitable for this design?

(Select one)
Select an answer

The Pre-Check tool has returned, “Warning: Not enough structural constraints defined in Load Case “Load Case 1”.” What can be done to eliminate this issue?

(Select one)
Select an answer

With regards to Structural Loads, what is the difference between using a Force Load and a Pressure Load?

(Select one)
Select an answer

46/46 questions left unanswered