00:03
Info.
00:04
Water Pro's engineering validation manager provides
00:07
an efficient way to review input
00:08
data for missing or unexpected values as well as connectivity issues.
00:14
You can check all network components for up to 60 rules
00:19
to begin. Double click the desired project dot
00:22
ARX file to open
00:24
Agis Pro.
00:25
Once the project starts,
00:27
click the info Water pro tab to open the info Water Pro ribbon
00:32
in the project panel, click initialize
00:36
from the model explorer command center tab expand the tools folder
00:40
and then double click engineering validation manager.
00:45
In the validation manager.
00:46
It is a good idea to click options and in the options,
00:50
dialog enable clear previous results automatically and then click.
00:54
OK.
00:56
In the validation manager, you can see several rows with rules I DS
01:01
warning messages levels and valid value ranges.
01:09
If you modify the criteria for multiple selected rows, then run a validation.
01:14
You can then sort the results based on warning levels. For example,
01:18
all violations are listed in the validation result tab of the message board.
01:23
You can expand the message board to display more rows.
01:27
You can also click a column heading to sort by that column
01:31
to see one of these violations in detail.
01:33
Double click it in the table and in the map,
01:36
the program zooms to and selects the corresponding feature.
01:42
You can also use the validation manager to check for
01:45
a single rule to be able to resolve just that one
01:48
to do so.
01:49
Back in the validation manager,
01:51
click the clear validation results icon of the validation,
01:54
you just ran to clear the message board
01:58
now to validate a single rule.
01:60
First click the uncheck all icon to clear all selected rows,
02:05
then check only row 39 to check for pipe diameters outside of the expected range.
02:11
Double click the valid value range field for row 39
02:15
enter a minimum of two
02:16
and a maximum of 24
02:18
with inclusives selected for both and then click, OK,
02:23
click to select add results to domain,
02:25
then click validate and close the validation manager
02:29
in the
02:30
GS. A value of 999 indicates an unknown diameter
02:35
diameters need to be assumed to run the hydraulic simulation
02:40
in the message board validation tab,
02:42
double click the first violation to zoom to and select the corresponding feature
02:48
in the model explorer attribute tab, change the diameter field to 10
02:53
and then click save.
Video transcript
00:03
Info.
00:04
Water Pro's engineering validation manager provides
00:07
an efficient way to review input
00:08
data for missing or unexpected values as well as connectivity issues.
00:14
You can check all network components for up to 60 rules
00:19
to begin. Double click the desired project dot
00:22
ARX file to open
00:24
Agis Pro.
00:25
Once the project starts,
00:27
click the info Water pro tab to open the info Water Pro ribbon
00:32
in the project panel, click initialize
00:36
from the model explorer command center tab expand the tools folder
00:40
and then double click engineering validation manager.
00:45
In the validation manager.
00:46
It is a good idea to click options and in the options,
00:50
dialog enable clear previous results automatically and then click.
00:54
OK.
00:56
In the validation manager, you can see several rows with rules I DS
01:01
warning messages levels and valid value ranges.
01:09
If you modify the criteria for multiple selected rows, then run a validation.
01:14
You can then sort the results based on warning levels. For example,
01:18
all violations are listed in the validation result tab of the message board.
01:23
You can expand the message board to display more rows.
01:27
You can also click a column heading to sort by that column
01:31
to see one of these violations in detail.
01:33
Double click it in the table and in the map,
01:36
the program zooms to and selects the corresponding feature.
01:42
You can also use the validation manager to check for
01:45
a single rule to be able to resolve just that one
01:48
to do so.
01:49
Back in the validation manager,
01:51
click the clear validation results icon of the validation,
01:54
you just ran to clear the message board
01:58
now to validate a single rule.
01:60
First click the uncheck all icon to clear all selected rows,
02:05
then check only row 39 to check for pipe diameters outside of the expected range.
02:11
Double click the valid value range field for row 39
02:15
enter a minimum of two
02:16
and a maximum of 24
02:18
with inclusives selected for both and then click, OK,
02:23
click to select add results to domain,
02:25
then click validate and close the validation manager
02:29
in the
02:30
GS. A value of 999 indicates an unknown diameter
02:35
diameters need to be assumed to run the hydraulic simulation
02:40
in the message board validation tab,
02:42
double click the first violation to zoom to and select the corresponding feature
02:48
in the model explorer attribute tab, change the diameter field to 10
02:53
and then click save.
InfoWater Pro's Engineering Validation Manager—commonly referred to as just the Validation Manager—provides an efficient way to review input data for missing or unexpected values as well as connectivity issues. You can check all network components for up to 60 rules.
In the Validation Manager, you can see several rows with rules, IDs, warning messages, levels, and valid value ranges. If you modify the criteria for multiple selected rows, then run a validation, you can then sort the results, based on warning levels, for example.
In the GIS, a value of 999 indicates an unknown diameter. Diameters need to be assumed to run the hydraulic simulation.
How to buy
Privacy | Do not sell or share my personal information | Cookie preferences | Report noncompliance | Terms of use | Legal | © 2025 Autodesk Inc. All rights reserved
Sign in to start learning
Sign in for unlimited free access to all learning content.Save your progress
Take assessments
Receive personalized recommendations