Calculate runoff amounts that help determine the size of stormwater control objects, such as ponds.
Tutorial resources
These downloadable resources will be used to complete this tutorial:
The goal in the catchment design process is to determine how much surface area of a catchment is impermeable, and how much runoff is caused by those impermeable areas. To do so, you must calculate the percentage impervious value, or “PIMP value,” which is the percentage of the catchment that is covered with tarmac, concrete, or other materials that rain cannot penetrate. InfoDrainage only accounts for runoff from those impermeable areas.
InfoDrainage assumes:
Keep in mind that these values work for this exercise, but they may need to be increased or decreased for other situations. These values are critical because they influence how much rainfall enters a drainage system in a model, and therefore dictate design elements like pipe and storage sizes.