Cannot adjust resolution factor and growth rates in "Advanced Meshing Controls" in Autodesk CFD 2019.2

Autodesk Support

Oct 8, 2023


Products and versions covered


Issue:

When trying to change growth rate including "Edge growth rate", "Volume growth rate", "Surface growth rate",  "Enhancement growth rate" and resolution factor to a value between 1.01~2 in CFD, an error message pops up indicating the parameter must be between a particular limit range, even thought the values specified are with in limits.
User-added image
User-added image

 

Causes:

Compatibility issues of CFD 2019.2 version with Windows default decimal symbol settings.

Solution:

Do the following for CFD 2019.2 users using on Windows language platform such as German, Hungarian and etc.
  • Go to Control Panel>Region>Additional setting>Decimal symbol.
  • please change it to "."
  • Restart your system for these changes to be implemented.

Products:

CFD;

Versions:

2019;


Was this information helpful?