Different value of integral and reduced bending moment or reduced force for panel cut in Robot Structural Analysis

Autodesk Support

Oct 8, 2023


Products and versions covered


Issue:

Different value of  integral and reduced bending moment, for panel cut in Robot Structural Analysis.

Example:
User-added image

Causes:

Possible causes

Incorrect moment or force selected for presentation in panel cut from Detailed  tab when local system is set for presentation. 

User-added image

Principal or Complex results presented for panel cut. 

image.png
 
 

Solution:

Select correct force or moment from Detailed tab for panel cut presentation.

Follow the steps:
  1. Open Results > Panel cuts.
  2. Co to Cuts tab.
  3. Activate required cut definition.
  4. Go to Detailed tab.
  5. Activate correct force or moment (for example activate Mxx when Myy was selected, or vice versa).
  6. Select no smoothing.
  7. Apply.
User-added image

Note:
When local direction is selected for cut presentation rotation axis for moment Mxx is defined as cut line direction.
 

 

Products:

Robot Structural Analysis Products;


Was this information helpful?


Need help? Ask the Autodesk Assistant!

The Assistant can help you find answers or contact an agent.


What level of support do you have?

Different subscription plans provide distinct categories of support. Find out the level of support for your plan.