How to set process settings to get Stress, Mises-Hencky result in Moldflow

Autodesk Support

Oct 8, 2023


Products and versions covered


Issue:

You would like to know the workflow for adding the Stress, Mises-Hencky result to your  Moldflow warp results. 

Solution:

  1. Open the process setting wizard,
  2. Select Advanced Options. 
  3. Select Edit next to Thermoplastic injection molding solver parameters
  4. Select the Stress Analysis tab
  5. Select Mises-Hencky stress under the Stress result(s) to output. Select OK twice and then Next to navigate to page 2 of the Process Settings Wizard
User-added image
          6.   On page 2 of the Process Settings Wizard, under Stress result(s) to output, again select Mises-Hencky stress
User-added image
 Select Finish to exit out of the Process Setting Wizard. 

         7.    Navigate to the Moldflow Insight icon and select options
User-added image

        8.    Under the Options tab, select Results
        9.    Select Add/Remove under Default results
User-added image

      10.   Scroll down to the Warp results folder until you locate Stress, Mises-Hencky (warp).  Select it.
      11.   Click the double arrow icon to add this result to the Default results and select OK
      12.   Stress, Mises-Hencky (warp) will not show as a Default result option