Section fails to be recognized as class 1 or 2 when thin walled option is disabled while steel code check according to EN-1993-1-1 in Robot Structural Analysis

Autodesk Support

Mar 29, 2025


Products and versions covered


Issue:

Section fails to be recognized as class 1 or 2. When thin walled option is disabled for member section is recognized as class 3 or 4 while steel code check according to EN-1993-1-1 in Robot Structural Analysis.

Example:
Member parameters

image.png
Recognized section class
image.png
 
 

Solution:

While steel code check according to EN-1993-1-1, clause 5.5 is used for section class verification. Criteria from table  5.2 and 5.5.2 (9) are checked. Section classification procedure does not depend on activating (or not) Thin walled section option in steel member type parameters.

Products:

Robot Structural Analysis Products;