& Construction

Integrated BIM tools, including Revit, AutoCAD, and Civil 3D
& Manufacturing

Professional CAD/CAM tools built on Inventor and AutoCAD
Integrated BIM tools, including Revit, AutoCAD, and Civil 3D
Professional CAD/CAM tools built on Inventor and AutoCAD
Import a level event and view the data.
Type:
Tutorial
Length:
3 min.
Tutorial resources
These downloadable resources will be used to complete this tutorial:
Transcript
00:03
Level events define level hydrographs for inputs to the network during a simulation.
00:08
A level hydrograph is typically used to represent seawater or river levels.
00:14
For 1D networks, level hydrographs can only be applied as an outfall node.
00:19
If a level hydrograph is applied to any type of node other than an outfall, it will be ignored during a simulation.
00:26
When carrying out 2D modeling in InfoWorks ICM, level hydrographs may also be applied to 2D boundary objects.
00:33
Level data is usually contained in a spreadsheet.
00:37
For this tutorial, you import a level event.
00:42
Before importing an inflow event, it is a good idea to create a new model group to store all your event data.
00:50
Right-click your existing Model Group and select New InfoWorks > Model Group.
00:57
In the New Name – Model Group popup, name the group “Ancillary Files” and then click OK.
01:04
From the Model Group, right-click the Ancillary Files group and select Import InfoWorks > Level > From event file.
01:16
In the Open dialog, navigate to the folder with the downloaded files for this tutorial and select Mean High Water Springs.lev.
01:26
Click Open.
01:28
The imported file appears under the Ancillary Files group.
01:33
Right-click Mean High Water Springs and select Open As.
01:37
From the Select Format popup, select Editor, and then click OK.
01:44
The level event contains profiles for multiple outfall locations.
01:49
An individual column is required for every node.
01:53
Right-click any cell and select Profile properties.
01:58
In the Properties window, you can set the Node reference and Pipe level or datum fields.
02:04
Be aware that when you are setting values for levels, all values should be relative to the same datum level.
02:10
A national datum level may be used, or you could choose your own datum, such as the invert level of the lowest conduit in the network.
02:18
If the datum level used is above the level of some or the entire network, the hydrograph may contain negative values.
02:25
In this case, a potentially large increase in level will occur if the default value of zero is used.
02:32
When you are finished working with the level data, close both the Properties and the Editor.
Video transcript
00:03
Level events define level hydrographs for inputs to the network during a simulation.
00:08
A level hydrograph is typically used to represent seawater or river levels.
00:14
For 1D networks, level hydrographs can only be applied as an outfall node.
00:19
If a level hydrograph is applied to any type of node other than an outfall, it will be ignored during a simulation.
00:26
When carrying out 2D modeling in InfoWorks ICM, level hydrographs may also be applied to 2D boundary objects.
00:33
Level data is usually contained in a spreadsheet.
00:37
For this tutorial, you import a level event.
00:42
Before importing an inflow event, it is a good idea to create a new model group to store all your event data.
00:50
Right-click your existing Model Group and select New InfoWorks > Model Group.
00:57
In the New Name – Model Group popup, name the group “Ancillary Files” and then click OK.
01:04
From the Model Group, right-click the Ancillary Files group and select Import InfoWorks > Level > From event file.
01:16
In the Open dialog, navigate to the folder with the downloaded files for this tutorial and select Mean High Water Springs.lev.
01:26
Click Open.
01:28
The imported file appears under the Ancillary Files group.
01:33
Right-click Mean High Water Springs and select Open As.
01:37
From the Select Format popup, select Editor, and then click OK.
01:44
The level event contains profiles for multiple outfall locations.
01:49
An individual column is required for every node.
01:53
Right-click any cell and select Profile properties.
01:58
In the Properties window, you can set the Node reference and Pipe level or datum fields.
02:04
Be aware that when you are setting values for levels, all values should be relative to the same datum level.
02:10
A national datum level may be used, or you could choose your own datum, such as the invert level of the lowest conduit in the network.
02:18
If the datum level used is above the level of some or the entire network, the hydrograph may contain negative values.
02:25
In this case, a potentially large increase in level will occur if the default value of zero is used.
02:32
When you are finished working with the level data, close both the Properties and the Editor.
Level events define level hydrographs for inputs to the network during a simulation. A level hydrograph is typically used to represent seawater or river levels.
For 1D networks, level hydrographs can only be applied as an outfall node. If a level hydrograph is applied to any type of node other than an outfall, it is ignored during a simulation. When carrying out 2D modeling in InfoWorks ICM, level hydrographs may also be applied to 2D boundary objects.
Level data is usually contained in a spreadsheet.
Before importing event files, it is a good idea to create a new model group to store all event data.
To import a level event file:
In the Model Group, the imported file appears under the Ancillary Files group.
The Level Event Editor contains profiles for multiple outfall locations. An individual column is required for every node.
In the Level Profile Properties dialog box, the Node reference and Pipe level or datum fields can be set.
Note: When setting values for levels, all values should be relative to the same datum level. A national datum level may be used, or datum can be chosen, such as the invert level of the lowest conduit in the network. If the datum level used is above the level of some or the entire network, the hydrograph may contain negative values. In this case, a potentially large increase in level will occur if the default value of zero is used.
How to buy
Privacy | Do not sell or share my personal information | Cookie preferences | Report noncompliance | Terms of use | Legal | © 2025 Autodesk Inc. All rights reserved
Sign in for the best experience
Save your progress
Get access to courses
Receive personalized recommendations
May we collect and use your data?
Learn more about the Third Party Services we use and our Privacy Statement.May we collect and use your data to tailor your experience?
Explore the benefits of a customized experience by managing your privacy settings for this site or visit our Privacy Statement to learn more about your options.